전화 (042)862-7500
팩스 (042)862-6500
sales@innowill.com
Performance Test
Test conditions
Inlet temperature [HOT] : 700℃
Inlet pressure : 104 ~106 kPa.a
Conducted the test with insulation.
Test conditions
nlet temperature [COLD] : 190℃
Inlet pressure [HOT]: 107 ~ 108 kPa.a [COLD] : 249 ~ 264 kPa.a
Mass flow rate [HOT] : 1.475 kg/s [COLD] : 1.414 kg/s
Conducted the test with insulation.